Fractional Dual-Tilt Control Scheme for Integrating Time Delay Processes: Studied on a Two-Tank Level System

Das, Dipjyoti and Chakraborty, Sudipta and Mehta, Utkal V. and Lloyd, G. Lloyds (2024) Fractional Dual-Tilt Control Scheme for Integrating Time Delay Processes: Studied on a Two-Tank Level System. IEEE Access, 12 . pp. 7479-7489. ISSN 2169-3536

[thumbnail of IEEE Access 2024_ FracDualTiltCont.pdf]
Preview
PDF
Download (3MB) | Preview

Abstract

Industrial processes of time delayed integrating type require sophisticated control methods because of their non-self-regulating nature. Literature presents fractional order controllers as possible solution to this problem and there is scope for further enhancing the performance of the existing solutions. Though fractional order controllers are capable of outperforming their integer order counterparts, it is evident in literature that the former controller designs are complex and hence analytical tuning procedures for the same are scarce. Hence, this paper presents a novel predictive strategy for time-delayed integrating processes based on two fractional-order tilt-derivative (FOT α D 1−α) controllers. These controllers are analytically designed with only two tunable parameters. These tuneables are computed using gain-and phase-margin specifications. In contrast to the previous methods, the presented scheme is more capable of eliminating input-load disturbances without adding complexity in terms of tunable parameters. In addition to the investigations carried out using three difficult benchmark plant models, the present design is also experimentally validated using a two-tank level control system to vindicate its efficacy. Through robust stability analysis, it is shown that the suggested strategy is capable of achieving stable closed-loop responses amid upto 50% perturbation in plant parameters.−α Fractional-order tilt-derivative C setpoint tracking FOT α D 1−α controller C d disturbance rejection FOT α D 1−α controller P Plant model K and L Gain and Time delay of plant model P m Delay-free part of plant model K t1 and K d1 Tilt and derivative gains in C K t2 and K d2 Tilt and derivative gains in C d α 1 and α 2 Fractional order parameter in C and C d M K S2 , M S2 Maximum sensitivities of servo and regulatory loops γ s and ϕ s GM, PM of servo loop γ r and ϕ r GM and PM of regulatory loop λ 1 , λ 2 Closed-loop time constant of servo and regulatory loops ω pcs ,ω gcs Phase and gain crossover frequencies of servo loop ω pcr ,ω gcr Phase and gain crossover frequencies of regulatory loop 2

Item Type: Journal Article
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > Robotics and Automation
Divisions: School of Information Technology, Engineering, Mathematics and Physics (STEMP)
Depositing User: Utkal Mehta
Date Deposited: 01 Feb 2024 03:27
Last Modified: 01 Feb 2024 23:22
URI: http://fjrepository.usp.ac.fj/id/eprint/14399